As-built
Documentation that records what was actually installed — rack positions, cable routes, port assignments — rather than what was designed.
Attenuation
Loss of optical power along a fiber, measured in dB per kilometre. See loss budgets.
Backbone cabling
Cabling between main distribution areas, telecom rooms and data halls, or between buildings. Usually high-count fiber.
Badging
The site owner's process for approving and issuing access credentials to workers. Often the longest step in mobilizing a crew.
Bi-directional OTDR
Taking OTDR measurements from both ends of a fiber and averaging them to get the true loss of each splice.
Cable tray / ladder rack
Overhead or underfloor pathway that supports cables in a data hall or telecom room.
Cassette
A module that transitions an MPO trunk to individual LC ports, usually mounted in a patch panel.
Change control
The process for approving any change inside a live facility before work starts.
Cleaver
A precision tool that cuts a fiber end flat before splicing. Ribbon cleavers cut a whole ribbon at once.
Cross-connect
A patch connection between two cabling segments, often in a meet-me room, linking customers and carriers.
dB (decibel)
The logarithmic unit used to measure optical loss.
Fusion splicing
Joining two fibers permanently by melting them together with an electric arc. See fiber splicing crews.
FTTH
Fiber to the home: fiber networks running to individual residences. See OSP and FTTH crews.
Innerduct
A small flexible conduit placed inside a larger conduit to protect and organize fiber cables.
Launch cable
A length of fiber attached between the OTDR and the link under test so the first connector can be measured. A receive cable does the same at the far end.
Liquidated damages (LDs)
Contract penalties per day of delay, a major reason schedules cannot slip.
Loss budget
The maximum total optical loss allowed in a link, calculated from its components. See the guide.
Mass fusion splicing
Splicing a full fiber ribbon — usually 12 fibers — in one operation. See ribbon vs single-fiber.
Meet-me room (MMR)
The room in a data center where carriers and customers interconnect.
MOP
Method of procedure: the approved, step-by-step plan for work in a live environment.
MPO / MTP
Multi-fiber push-on connectors carrying 8, 12, 16, 24 or more fibers. MTP is a brand of MPO. See MPO polarity.
Multimode fiber (OM3, OM4, OM5)
Fiber with a larger core used for short links inside data centers. OM4 jackets are usually aqua.
OSP
Outside plant: cabling outside buildings — aerial, underground, between buildings.
OTDR
Optical time-domain reflectometer: a tester that sends pulses of light down a fiber and reads the reflections to locate and measure splices, connectors and faults. See OTDR testing.
Per diem
A daily allowance for meals and incidentals for traveling workers.
Polarity
Making sure transmit fibers at one end connect to receive fibers at the other.
Punch list
The list of remaining defects and incomplete items before a phase is accepted. See punch and QA/QC crews.
Rack and stack
Installing cabinets and equipment, cabling and patching them, and documenting the result. See rack and stack crews.
Ribbon fiber
Fibers bonded side by side in a flat or rollable ribbon, typically 12 wide, for high-count cable and mass fusion splicing.
Rotation
A work schedule for traveling crews, such as 21 days on and 7 days off.
Single-mode fiber (OS2)
Fiber with a small core used for long links and high-speed optics. OS2 jackets are usually yellow.
Splice closure / enclosure
A protective housing that holds splice trays and splices.
Structured cabling
A standards-based cabling system of pathway, cable, connectors and administration. See structured cabling crews.
TIA-568
The ANSI/TIA family of standards for telecommunications cabling, including fiber component limits.
TIA-606
The ANSI/TIA administration standard for labeling and records. See TIA-606 labeling.
TIA-942
The ANSI/TIA standard for data center telecommunications infrastructure.
Tier 1 / Tier 2 testing
Tier 1 measures end-to-end loss, length and polarity; Tier 2 adds an OTDR trace.
White space
The data hall floor area where IT equipment racks sit, as opposed to gray space for power and cooling.
RELATED
- FIELD GUIDEMPO/MTP polarity explained for project managersPolarity makes sure the transmit fiber at one end reaches the receive fiber at the other. On MPO/MTP systems, polarity depends on three part…
- FIELD GUIDEFiber loss budgets: splice, connector and cable limitsA fiber loss budget adds up the maximum allowed loss of every component in a link: cable attenuation (loss per kilometre times length), each…
- FIELD GUIDERibbon splicing vs single-fiber splicingRibbon (mass fusion) splicing joins a whole ribbon — usually 12 fibers — in one operation, so it is dramatically faster per fiber on high-co…
- SERVICEOTDR testing and fiber certification crewsHardline test crews certify fiber with Tier 1 (light source and power meter) and Tier 2 (bi-directional OTDR) testing, then deliver results …
- COMPANYFrequently asked questionsHardline supplies foreman-led fiber and low-voltage crews to data center and FTTH builds nationwide. Crews typically mobilize in 5–7 days on…